Die genannten Informationen entbinden den Kunden nicht von selbständigen Applikationsprüfungen.
Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
37 37 TIGER ELECTRONICS THERMAL MANAGEMENT TIGER ELECTRONICS FANS + ACCESSORIES Die genannten Informationen entbinden den Kunden nicht von selbständigen Applikationsprüfungen.
Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.
• High air output • Long service life • Ball bearing fans • Ready for connection • Optical function indicator Compact high performance fan tray for enforced circulation of air in switch and server enclosures and for concerted cooling of 19“ component groups.
Natural convection is improved and the formation of localised hot pockets is avoided.
Also available with integrated thermostat (see photo).
Axial fans, ball bearing service life 50,000h at 25°C (65% RH) fan body aluminium, rotor plastic Material front panel aluminium, bright anodised casing steel sheet, electrogalvanized Optical indicator integrated in front panel Connection appliance power inlet on rear of casing, plug included Fitting position horizontal (direction of air upwards) Operating/ Storage temperature -45 to +70°C (-49 to +158°F) Protection type IP20 Protection class I (earthed) Approvals UL High-performance 19“ Fan Tray • LE 019 Series Note: We recommend using the fan tray without integrated thermostat in combination with our dual thermostat (ZR 011 Art.
No.
01176.0-00) for regulating temperature in electronic enclosures and for protection against overheating due to possible fan failure.
The dual thermostat regulates the operation of the fan tray and – when connected to a signal device – also triggers an early warning if the enclosure interior temperature rises above a set limit.
When using a fan tray with integrated thermostat, the use of an additional thermostat (KTS 011 Art.
No.
01141.0-00) provides the extra safety of activating a signal device.
High-performance 19“ Fan Tray - Leistungsstarker 19“ Lüftereinschub LE 019 Series Art.
No.
Model No.
of Fans Operating Air volume, Power Average Speed (rpm-1) Impact Weight voltage free flow consumption noise level pressure (approx.) Art.
Nr.
Ausführung Anzahl Betriebs- Luftleistung Leistungs- Schalldruck Drehzahl Stat.
Druck Gewicht Lüfter spannung aufnahme (ca.) 01930.0-00 w/o thermostat 3 230VAC, 50Hz 486m³/h 45W 55 db (A) 2600 min-1/50Hz 74 Pa 3.00kg 01930.1-00 w/ thermostat 3 230VAC, 50Hz 486m³/h 45W 55 db (A) 2600 min-1/50Hz 74 Pa 3.40kg [0 to +60°C] 01940.0-00 w/o thermostat 6 230VAC, 50Hz 972m³/h 90W 57 db (A) 2600 min-1/50Hz 74 Pa 5.30kg 01940.1-00 w/ thermostat 6 230VAC, 50Hz 972m³/h 90W 57 db (A) 2600 min-1/50Hz 74 Pa 5.70kg [0 to +60°C] 01950.0-00 w/o thermostat 9 230VAC, 50Hz 1458m³/h 135W 58 db (A ) 2600 min-1/50Hz 74 Pa 7.80kg 01950.1-00 w/ thermostat 9 230VAC, 50Hz 1458m³/h 135W 58 db (A) 2600 min-1/50Hz 74 Pa 7.90kg [0 to +60°C] 01931.0-00 w/o thermostat 3 120VAC, 60Hz 576m³/h 45W 55 db (A) 2900 min-1/60Hz 88 Pa 3.00kg 01931.1-00 w/ thermostat 3 120VAC, 60Hz 576m³/h 45W 55 db (A) 2900 min-1/60Hz 88 Pa 3.40kg [0 to +60°C] 01941.0-00 w/o thermostat 6 120VAC, 60Hz 1152m³/h 90W 57 db (A) 2900 min-1/60Hz 88 Pa 5.30kg 01941.1-00 w/ thermostat 6 120VAC, 60Hz 1152m³/h 90W 57 db (A) 2900 min-1/60Hz 88 Pa 5.70kg [0 to +60°C] 01951.0-00 w/o thermostat 9 120VAC, 60Hz 1728m³/h 135W 58 db (A ) 2900 min-1/60Hz 88 Pa 7.80kg 01951.1-00 w/ thermostat 9 120VAC, 60Hz 1728m³/h 135W 58 db (A) 2900 min-1/60Hz 88 Pa 7.90kg [0 to +60°C] w/o thermostat: Ohne Thermostat - w/ thermostat: Mit Thermostat Axiallüfter, Kugellager Lebensdauer 50.000 h bei 25 °C/77 °F (65 % rF) Material Frontblende: Aluminium, hell eloxiert Gehäuse: Stahlblech, galv.
verzinkt Optische Funktionsanzeige integriert in Frontblende Anschluss Kaltgerätestecker rückseitig eingebaut inkl.
Kaltgerätesteckdose Einbaulage horizontal (Luftrichtung nach oben) Einsatz-/ Lagertemperatur -45 bis +70 °C (-49 bis +158 °F) Schutzart IP20 Schutzklasse I (Schutzleiter) Approbationen UL Anwendung in 19“ Schränken: Beim Lüftereinschub ohne integriertem Thermostat empfehlen wir die Kombination mit unserem Zwillingsthermostat (Art.
Nr.
01176.0-00) zur Temperaturregelung und zum Anschluss eines op- tischen oder akustischen Signalgebers als Warnfunktion bei Überhitzung im Falle eines Ausfalls der Lüfter.
Beim Lüftereinschub mit integriertem Thermostat kann zur Temperaturüberwachung zusätzlich ein Thermostat (KTS 011 Art.
Nr.
01141.0-00) als Warnkontakt geschaltet werden, der - angeschlossen an einen Signalgeber - beim Ausfall der Lüfter reagiert und vor Überhitzung ein Signal gibt.
• Hohe Luftleistung • Lange Lebensdauer • Kugelgelagerte Lüfter • Anschlussfertig • Optische Funktionsanzeige Kompakter, leistungsstarker Lüftereinschub zur Umwälzung der Luft in 19“ Elektronikschränken zur gezielten Wärmeab- fuhr an Baugruppen.
Die Eigenkonvektion der Schrankober- fläche wird verbessert und das Entstehen von Wärmenestern verhindert.
Erhältlich auch mit integriertem Thermostat (siehe Abbildung).